Adloun

Physics (Grade 10, Lebanon) · Chapter 6 · Tutorial exercise

Workshop electrical network with switching of a motor and a furnace

Electric circuits · B. Mixed circuits and networks with several loops · level 3 (hard)

Statement

A regulated laboratory power supply can be modeled by a linear generator followed, in the main branch, by a line ohmic conductor of resistance and a main ammeter of negligible resistance. The main line ends at two distribution terminals and to which a voltmeter measuring the voltage is permanently connected. Between terminals and , the following can be connected in parallel by means of two independent switches and :

  • Branch 1 (controlled by ): a small heat-treatment furnace that can be modeled as an ohmic conductor of resistance .
  • Branch 2 (controlled by ): an electric ventilation motor .

Part A — Calibration of the generator ( open):

  1. When the two switches and are open, the voltmeter connected between and reads .
  2. When only is closed ( remaining open), the furnace is alone in service between and and the main ammeter reads . Deduce from these two measurements the electromotive force and the internal resistance of the generator, as well as the voltage across the furnace.

Part B — Simultaneous operation of the furnace and the motor ( and closed): The two switches and are now closed. The generator then delivers a main current into the line , which splits at junction into a current in the furnace and a current in the motor .

  1. Express the new voltage in the main branch as a function of , then express , and as functions of .
  2. By applying the junction law at junction (), show that satisfies the equation: then calculate the numerical value of and deduce the currents , and .
  3. Calculate, in this mode of simultaneous operation, the useful mechanical power of the motor, the thermal power of the furnace and the overall efficiency of the installation (ratio of to the total power generated by the generator).

Solution

Part A:

  1. When and are open, no current flows in the main branch (). The voltage drop in and in is zero, so the voltmeter directly measures the electromotive force of the generator:
  2. When only is closed, the generator , the line and the furnace form a series circuit carrying . According to Pouillet's law: We get the internal resistance of the generator: (Remark: the total resistance of the main branch is therefore ). The voltage across the furnace is then:

Part B:

  1. In the main branch of total resistance , the voltage between and is written: In the two receiving branches in parallel between and :
  • Branch 1 (furnace ): ;
  • Branch 2 (motor ): .
  1. The junction law at () does give the stated equation: Now . The equation can therefore be rewritten: We deduce: The three currents are then:
  • ;
  • ;
  • . (Check: ).
  1. Energy balance:
  • Useful mechanical power of the motor: .
  • Useful thermal power of the furnace: .
  • Total power generated by the generator: .
  • Overall efficiency of the installation:

What the exercise establishes: Handle a complete problem of electrokinetics combining the experimental identification of a real generator, the setting up of the equations of an active parallel network and an efficiency balance.

Similar exercises

The course of the chapter · All the exercises of the chapter