Physics (Grade 11, Lebanon) · Chapter 3 · Tutorial exercise
Marine sonar: detecting a school of fish and the seabed
Reception of sound and the human ear · C. Ultrasound, sonar and medical ultrasound imaging · level 2
Statement
A trawler equipped with a vertical sonar sails in an area where the speed of ultrasound in seawater is . At the instant , the transducer emits a brief ultrasonic burst of frequency . The sonar receiver records two successive echoes: a first echo of moderate amplitude at the instant (reflection on a school of fish) and a second, stronger echo at the instant (reflection on the rocky bottom).
1) Why is ultrasound () used rather than audible sound () to equip the sonar of a ship? Calculate the corresponding wavelengths in seawater.
2) Calculate the depth of the school of fish, the total depth of the seabed and the height at which the school of fish moves above the bottom.
3) What is the maximum emission rate (maximum number of bursts per second, ) that the sonar can use at this place if the echo from the seabed must always return before the next burst is emitted?
Solution
1) Advantage of ultrasound and wavelengths. In seawater (): Thanks to their small wavelength (), ultrasonic waves form a highly directional beam, are reflected by small targets (fish) and do not disturb the crew (inaudible).
2) Depths of the school of fish and of the bottom. The school of fish is therefore at a height above the seabed.
3) Maximum repetition rate of the bursts. To avoid any ambiguity between two successive bursts, the repetition period must be greater than or equal to the round-trip time of the most distant echo: , hence:
What the exercise establishes: Interpret an echogram with multiple echoes () and relate the maximum range of a sonar to the minimum period separating two emitted pulses.
Similar exercises
- Measuring the speed of ultrasound in air with two receivers solved
- Impedance matching and mechanical amplification in the middle ear solved
- Resonance of the ear canal, Eustachian tube and cochlear coding solved
- Transcranial brain ultrasound (A-mode) solved
- From clinical audiometry to the ultrasonic parking sensor solved
The course of the chapter · All the exercises of the chapter