Adloun

Physics (Grade 12 General Sciences, Lebanon) · Chapter 9 · Tutorial exercise

Measuring the refractive index of a gas by the shift of fringes

Interference of light · B. Thin parallel-faced plate and interference in white light · level 2

Statement

To measure with extreme precision the refractive index of a gas very close to one, two identical transparent cells and , of the same inner length and closed by identical flat parallel windows, are placed behind the two Young's slits and . The setup is lit by a laser of wavelength in vacuum .

Initially, the two cells and are both emptied of air (index of vacuum ). Gaseous carbon dioxide is then gradually and slowly let into the cell (while remains under vacuum) until normal atmospheric pressure is reached. A photoelectric sensor placed at the geometric center () of the screen counts exactly interfringe distances passing by during the filling.

1) Why are two identical cells placed in front of and rather than a single cell in front of ? What is the position of the central fringe when both cells are under vacuum?

2) Express the optical path difference introduced between the two paths when the cell is filled with the gas of index and the cell is under vacuum ().

3) Relate to the number of interfringe distances that passed by at and to the wavelength , then calculate the value of and deduce the refractive index of carbon dioxide to seven significant figures.

4) Limiting case. What is the final interference state (bright or dark) at at the end of the filling? What minimum thickness of gas (or what minimum change in index ) can this setup detect if a shift of one tenth of an interfringe distance can be estimated ()?

Solution

The strategy. The glass walls of the two identical cells introduce exactly the same optical path on both paths and cancel each other out. Only the column of gas of length and index in creates a path difference .

1) Role of the two identical cells. The glass windows that close a cell have a thickness that is not negligible compared with . By placing two strictly identical cells in front of and , the optical paths crossed in the glass walls are equal on both paths and cancel out by subtraction: when both cells are under vacuum, the path difference at is strictly zero () and the bright central fringe of order is centered on .

2) Optical path difference created by the gas. Over the length , path crosses the gas of index (optical path ) while path crosses the vacuum of index (optical path ). The lengthening of the optical path along path is therefore:

3) Calculating the index of carbon dioxide. Each time the optical path increases by one wavelength , the fringe system shifts by one interfringe distance and one complete bright fringe passes by at . For interfringe distances passing by: Numerical application with and : The refractive index of carbon dioxide is therefore:

4) Limiting case: final state at and sensitivity of the refractometer.

  • Initially at , the interference order was (bright central fringe). After interfringe distances have passed by, the new interference order at is (half-integer): at the end of the filling, the point is therefore occupied by the center of a dark fringe (the 36th dark fringe with respect to ).
  • For a minimum detectable shift , the smallest measurable change in index is: Interferometry thus makes it possible to measure a refractive index to within one millionth!

What the exercise establishes: Counting the number of fringes passing by a fixed point depends neither on nor on : it is the principle of high-precision interference refractometers.

Similar exercises

The course of the chapter · All the exercises of the chapter