Volumetric titration by redox reaction
Course · Chemistry (Grade 11, Lebanon), chapter 4 · Lebanon, Grade 11 · the beginning of the chapter, the rest on Adloun
Whether it is a matter of checking the iron(II) content of a pharmaceutical anti-anemia tablet, verifying the volume strength of a medical hydrogen peroxide solution, measuring the sulfur dioxide content of a white wine or determining the chlorometric degree of a commercial bleach, the analytical chemist must determine quickly and precisely the unknown molar concentration of an oxidizing or reducing species in solution. The reference method in the laboratory is volumetric analysis (or titration) by oxidation-reduction reaction. This fourth chapter sets out the theoretical and experimental principles of redox titration, then examines in depth the two main colorimetric methods of the curriculum: permanganate titration (manganimetry, using the self-indicating permanganate ion) and direct or indirect iodometry (using the iodine/iodide ion couple and sodium thiosulfate in the presence of starch solution).
Curriculum: LB-1S
Required skills
- Define a volumetric analysis (titration), identify the titrated reactant and the titrant, and state the three essential properties of a reaction used for titration (unique, complete, fast).
- Draw and label the experimental setup of a volumetric titration and describe the glassware procedure (volumetric pipette, graduated buret, Erlenmeyer flask).
- Define the equivalence point of a titration and establish the fundamental stoichiometric relation at equivalence .
- Interpret and use a permanganate titration in sulfuric acid medium (detecting the equivalence point by the persistence of the pink-purple color of the ions).
- Interpret and use a direct or indirect iodometric titration (reaction between and , role and time of addition of the starch solution).
4.1 General principle of a redox volumetric titration
4.1.1 Purpose, vocabulary and conditions on the titration reaction
To titrate (or assay) a dissolved chemical species means to determine its unknown molar concentration in a solution. In a volumetric titration by oxidation-reduction reaction, a precisely known volume of a solution containing the species to be titrated (called the titrated reactant) is made to react with a solution of precisely known molar concentration (called the titrant), until the change of limiting reactant is reached, which is detected by a sudden change in color of the reaction mixture.
- If the titrated reactant is a reducing agent (for example , , ), the titrant chosen is an oxidizing agent (, ...).
- If the titrated reactant is an oxidizing agent (for example , , ), the titrant chosen is a reducing agent (, ...).
For an oxidation-reduction reaction with balanced equation:
to be usable as the basis of a precise volumetric titration, it must have three fundamental properties:
- Be complete (or quantitative): the reaction must consume the limiting reactant entirely at each addition. On the scale of standard potentials at , this requires that .
- Be fast: the final state must be reached almost instantly after the addition of each drop of titrant solution so that the operator does not overshoot the equivalence volume (if the reaction is kinetically slow when cold, as between and oxalic acid , the reaction mixture is warmed to about or a catalyst is used).
- Be unique (unambiguous and selective): no side reaction must consume the titrant or the titrated reactant in parallel with the main reaction.
4.1.2 Definition of the equivalence point and fundamental stoichiometric relation
The equivalence point of a titration is the particular state of the chemical system in which the titrated reactant initially present in the reaction vessel and the titrant poured since the beginning of the titration (volume poured , called the equivalence volume) have been introduced exactly in the stoichiometric proportions of the balanced titration equation. At equivalence, the two reactants (titrated and titrant) are simultaneously and entirely consumed: there is a change of limiting reactant.
- Before equivalence (): the titrant added is the limiting reactant (it disappears completely as soon as it falls into the beaker) and the titrated reactant is in excess.
- At equivalence (): neither the titrated reactant nor the titrant remains in solution; only the products of the reaction and the spectator ions are present.
- After equivalence (): the titrated reactant is completely used up (it is now the limiting reactant) and the extra titrant added accumulates in solution (which causes the color change as soon as the first drop is added in excess).
Exercises of the chapter
- Permanganate titration of an iron(II) sulfate solution partly oxidized by air solved
- Titration of an oxalic acid solution and determination of a commercial purity solved
- Permanganate titration of a steel after acid attack solved
- Direct titration of a Lugol's solution with sodium thiosulfate solved
- Indirect iodometric titration of a potassium dichromate solution solved
- Determining the potassium iodate content of an iodized table salt solved